Composite outcomes in 2.25-mm drug eluting stents: a systematic review
Composite outcomes in 2.25-mm drug eluting stents: a systematic review
Lee et al., 2015 | Cardiovasc Revasc Med | Systematic Review
Citation
Lee Justin Z, Singh Nirmal, ... Lee Kwan S. Composite outcomes in 2.25-mm drug eluting stents: a systematic review. Cardiovasc Revasc Med. 2015-Jun;16(4):237-42. doi:10.1016/j.carrev.2015.03.008
Abstract
BACKGROUND: Coronary atherosclerosis often involves small-caliber coronaries, yet the safety and efficacy of 2.25-mm DES have been poorly defined, with a general lack of separation of 2.25 with 2.5-mm performance. No randomized head-to-head 2.25 mm DES studies have been reported. There are several single-arm prospective studies, and we aim to systematically review all published specific 2.25-mm data to estimate composite DES-specific performance and highlight current knowledge gaps. METHODS: We performed a systematic literature search of PubMed, EMBASE, Web of Science and Cochrane database for clinical trials of 2.25-mm DES. Angiographic and composite clinical outcomes were compared with descriptive statistics. RESULTS: 2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-mm, and 0.16 ± 0.41-mm and mean diameter restenosis for SES, PES, and EES were 29.5 ± 6.2%, 34.7 ± 4.2%, and 20.9 ± 22.5%. Reported stent thrombosis rates for 2.25-mm DES were low ranging from 0% to 2.2% in up to 24-months of follow-up. CONCLUSIONS: This systematic review summarizes and tabulates all available specific data on 2.25-mm DES. Based on our descriptive analysis, 2.25-mm DESs have a favorable safety and efficacy profile for the treatment of very small coronary lesions.
Key Findings
2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-m
Outcomes Measured
- Requires manual extraction
Population
| Field | Value |
|---|---|
| Population | See abstract |
| Sample Size | See abstract |
| Age Range | See abstract |
| Condition | See abstract |
MeSH Terms
- Coronary Artery Disease
- Coronary Restenosis
- Drug-Eluting Stents
- Everolimus
- Humans
- Paclitaxel
- Sirolimus
Evidence Classification
- Level: Systematic Review
- Publication Types: Journal Article, Systematic Review
- Vertical: chromium
Provenance
- PMID: 25976630
- DOI: 10.1016/j.carrev.2015.03.008
- PMCID: Not in PMC
- Verified: 2026-04-09 via PubMed E-utilities API